Overview

Oil & gas camps support rotational workforces on field, pipeline and turnaround projects. International EPCs and camp management firms typically procure modular accommodation with strict HSE manuals and security perimeter requirements.

Compared with S1/S2: higher bed standard for management tiers, induction/training rooms, dual guard posts, and formal HSE document coordination.

Typical project profile

DimensionTypical range
Headcount200–1000+
Duration1–5 years (turnaround camps shorter)
Accommodation2–4 beds/room workers; 1–2 beds/room management
StandardsProject HSE manual, client SP/TP
SecurityPerimeter fence; camp/work face separation

Recommended building systems

  • —Primary: P1 turnkey camp packages
  • —Management units: P4 welded office + P1 meeting pods
  • —Induction / training: P3 expandable 80–120 m² (within M-OFF or separate code)
  • —Stacked units are outside the standard scope. Any stacking needs a structural calculation and corner-casting alignment; improvised stacks without either are not recommended.

Configuration tiers

Tier A · 300 workers

ModuleQuantitySystemNotes
M-DORM240 worker + 60 mgmt/supervisionP1Zoned separate blocks
M-OFF120 m² project + 60 m² meetingP4—
M-CANT160 m²P1Cold/hot storage zoning
M-SANGender-separated + 1 accessible setP1—
M-CLN60 m² with observation bedP1—
M-GUA2 guard postsP1—
M-STRGeneral storage onlyP1Hazmat not in modular scope

Tier B · 600 workers

ModuleQuantitySystemNotes
M-DORMDual living zones (Phase 1/2) or single large campP1—
M-OFF / M-CANT / M-SAN / M-CLNScaled; HSE zoning plan mandatoryP1—

Site layout & camp planning

  • —Worker camp and work face separated; vehicle screening at dual guard posts.
  • —Module numbering linked to gate registration SOP (buyer security).
  • —Induction/training room near camp entry.
  • —Hazmat storage in dedicated non-modular facilities.

Technical & HSE requirements

ItemSupplier coordination scope
Material certificatesCore fire rating, steel mill certs per order
Detail drawingsFoundation, anchorage, grounding schematic
Method statementFor buyer HSE submission (P1)
ATEX / explosion-proofModular buildings not ATEX-rated by default; use dedicated equipment rooms

Phasing & delivery

Each batch includes module location plan mapped to on-site numbering.

BatchTypical content
1Management office + first 120 beds
2Main dorm ~200 beds
3Canteen + remaining dorm + clinic
4Sanitary, storage, guard posts

Installation & handover

  • —Installation period aligned to pipeline welding or field milestones.
  • —Buyer: foundations, perimeter, main MEP, security operations.
  • —Supplier: delivery list, unit labels, arrival photos, module IDs.

Request specification

  • —All S1 fields, plus:
  • —Client / HSE specification reference
  • —Camp bed standard (2-bed vs 4-bed rooms)
  • —Security perimeter requirements
  • —Phased occupancy dates per milestone

Typical specifications for reference only. Final dimensions, materials and quantities per signed drawings and order.